用于将SEM样品加热以达到不同的高温及恒定在一定温度下观察样品的相变情况。带有的散热保护装置,可保护SEM 内的其他组件。
Heating Stages for SEM
Many metallurgical and materials science studies benefit from specimen heating in the SEM. Dynamic observations of phase transitions and other microstructural changes with respect to temperature can be informative for materials research and failure analysis. Using specialized equipment, dynamic gas reactions can be studied. The effect of re-crystallisation can be observed using the combination of specimen heating and electron backscattered diffraction (EBSD).


Heating stage modules

H1000 Series modules are all designed to interface easily to most standard SEM stages, using a thermally isolated stage interface.

Water-cooled shielding and retractable shutters are provided for SEM protection with H1002 and H1004 high temperature modules. For the highest temperature module (H1004), a flow switch provides a safety furnace power cut-off in case of insufficient flow in the water cooling circuit.

The heating modules are supplied complete with power supply, temperature sensor and a digital temperature controller.

‘Hot’ imaging detector

Standard secondary electron imaging can become unreliable at high temperatures, as the number of thermal electrons and the amount of light emitted from the specimen increases. Furthermore some modern microscopes automatically reduce the gain of the SE detector when larger probe currents are used, even though the SE signal can be limited with hot specimens.

Gatan has developed a special ‘hot’ backscattered electron detector, which rejects the light emitted at high temperatures. MiniHBS is a retractable photomultiplier-based BSED which can be fitted to any suitable SEM chamber port. It is supplied complete with integral power supply plus brightness and contrast controls and provides an imaging signal as a configurable analogue voltage. A dedicated scan synchronous AUX or BS input is required for imaging on the SEM monitor. Optimum imaging performance may be achieved with a dedicated Digital Beam Control system such as DigiScan II™ which is optimised for scanning flexibility and extracting small imaging signals..

For metallurgy and materials science studies, phase transitions and inclusions and microstructural properties.

All heating stages are modules which are interfaced to the standard SEM stage. The system is complete with power supply, temperature controller and sensor.

Gatan also supplies heating options integrated into tensile stages for dynamic testing specimens in the SEM at elevated temperature.


C1003

Cooling / heating stage module -185°C to +400°C



H1001

Heating stage module to +500°C. Uses dovetail sample holder, compatible with airlock operation.



H1002

Heating stage module to +750°C. Specimen is mounted directly onto module surface. A shutter protects the pole piece. Water cooled base plate.



H1002D

Heating stage module, suitable for EBSD studies. Sample platform is tilted at 70 degrees.
Maximum sample size 5mm x 5mm x 2mm, otherwise specifications are as H1002. Special versions of the H1001 and H1002 are available for use with EBSD.



H1004

Heating module to +1250°C. The module jacket and shutter are water cooled. Biasing reduces the effect of thermal electrons. SE imaging at high temperature cannot be guaranteed due to possible light detection by SE equipment. C1000XYZ may be required.

Hotter stages reaching temperatures as high as +1500°C may be available by
special request.



C1000XYZ

Example C1000XYZ from large chamber SEM

Replacement SEM door and X,Y, Z stage with manual micrometer stage movement. May be required for H1005 product range depending on SEM stage, or may provide additional flexibility.



Optional

An optional capilliary gas injector and needle valve are available for the H1004 for studying in-situ gas reactions.


MiniHBS

MiniHBS, retractable ‘hot’ back scattered electron detector, for imaging at high temperatures. Includes power supply and control unit.

Heating Stages for SEM由科扬国际贸易(上海)有限公司 为您提供,如您想了解更多关于Heating Stages for SEM报价、货号、参数等信息 ,欢迎来电或留言咨询。

"Heating Stages for SEM"相关资源
相关类目
离心管 垃圾袋 过滤瓶/过滤器 防护眼镜 色谱柱 其他配件耗材
相关商机
STEMPack X-ray Microscopy 消磁仪 Microtest-Tensile Stages for SEM C1010 Airlock System C1002 Liquid Nitrogen cold stage CF302M Helium cooled stage module CF302 Continuous Flow Helium Stage MiniCL-阴极荧光谱仪 ParaCL-阴极荧光谱仪 XiCLone-Spectrum Imaging Opition for Mon 930 Plunge freezing 648 Double Tilt Vacuum Transfer Holder VTST4006 Single Tilt Vacuum Transfer Hol 927 Dual Orientation Room Temperature Ho
企点客服www企点营销 企点客服www企点营销
免责声明

本网页所展示的有关【Heating Stages for SEM】的图片/价格/参数等所有数据信息由会员【科扬国际贸易(上海)有限公司 】或网友提供,由仪器仪表网会员【科扬国际贸易(上海)有限公司 】或网友自行对图片/价格/参数等所有数据信息的真实性、准确性和合法性负责,本平台(本网站)仅提供展示服务,请谨慎交易,因交易而产生的法律关系及法律纠纷由您自行协商解决,本平台(本网站)对此不承担任何责任。您在本网页可以浏览【Heating Stages for SEM】有关的信息/图片/价格等及提供 【Heating Stages for SEM】的商家公司简介、联系方式等信息。

在您的合法权益受到侵害时,请您在相关信息上架展示七日内,致电400-803-5117,我们将竭诚为您服务。否则,本网站视为您主动放弃相关权益,我们对此不承担任何责任。感谢您的关注与支持!